Heating and boiler glossary
A technician’s report, a boiler manual or a quote often contains terms whose meaning is not obvious to a homeowner. In this glossary we briefly explain, in alphabetical order, the most common terms: boiler types, their main parts, heating system equipment and safety terms. For many terms we point to articles where the topic is covered in more detail.
In brief
- The terms are arranged in Lithuanian alphabetical order. Choose a letter in the table of contents.
- The explanations are general. The limits and settings of a specific boiler are given in its manufacturer’s manual.
- Some of the devices described are inside the boiler, next to gas or electrical parts. Do not dismantle or adjust them yourself: this is work for a certified specialist.
Before the heating season it is handy to check things against a list. The printable boiler checklist (PDF, in Lithuanian) covers only the checks you can safely do yourself without opening the boiler casing.
A
Safety valve
A valve that opens and releases some water when the pressure in the heating system exceeds a set limit. In domestic boilers it is usually about 3 bar (the exact value is marked on the valve). If the valve drips repeatedly, this points to another fault, most often in the expansion vessel or the filling valve; more in the article “Boiler is dripping”.
Open-flue (atmospheric) boiler
A boiler with an open combustion chamber: it takes the air needed for combustion from the room it stands in, and the flue gases go up the chimney by natural draught. That is why the room must be ventilated and the ventilation openings must not be covered or blocked. Most such boilers are of an older generation and non-condensing.
B
Water heater
A hot water storage tank in which water is kept heated. A cylinder connected to a boiler is heated through an internal coil heat exchanger, to which the boiler supplies heating water; in everyday speech an electric water heater is also called a boiler. A cylinder is used when hot water is needed at several taps at the same time.
C
Short cycling
The boiler switching on and off frequently at short intervals. The most common causes: boiler output too high for the building, unsuitable settings, closed radiators or poor circulation. Short cycling increases wear on parts and fuel consumption; more in the article “Boiler switches on often”.
Circulation pump
A pump that drives water around the closed heating circuit: through the boiler’s heat exchanger, pipes and radiators. In wall-hung boilers it is built into the boiler; larger systems also have separate pumps for each circuit. Newer pumps adjust their speed to the system’s demand.
D
Combustion analysis
Measuring the composition of the flue gases with a flue gas analyser, done during annual servicing. The levels of carbon monoxide (CO) and oxygen (O₂) or carbon dioxide (CO₂) are measured; from the results the specialist assesses whether the boiler burns properly. The permitted limits are set by the boiler manufacturer; more in the article “Carbon monoxide and gas safety”.
Gas valve (gas block)
An assembly inside the boiler that opens, closes and regulates the gas supply to the burner on commands from the control board. It also has a safety function: if the flame goes out, the valve shuts off the gas. Only a certified specialist may adjust, replace or dismantle the gas valve.
Flue
The duct through which flue gases are carried from the boiler to the outside. It may be a chimney, a liner fitted into a chimney, or a pipe taken out through a wall or roof. The flue must be sealed and unobstructed, and its terminal outside must be clear; more in the article “Getting ready for the heating season”.
E
ErP and energy class
ErP refers to the European Union requirements for energy-related products. For space heaters they are set by Regulation (EU) No 813/2013 (minimum seasonal efficiency) and Regulation (EU) No 811/2013 (energy label). Because of these requirements, newly supplied domestic gas boilers are mostly condensing, and space heaters must carry an energy label showing their energy class.
G
Output (kW)
The maximum amount of heat a boiler can produce per unit of time, measured in kilowatts (kW). The technical data of combi boilers often give two values: heating output and hot water output. The required heating output is calculated from the building’s heat losses; too much output can cause short cycling.
Underfloor heating
A heating method in which pipes carrying heating water are laid in the floor structure. It needs a lower water temperature than radiators, so it works well with condensing boilers and heat pumps. When radiators are heated from the same heat source, underfloor heating usually gets a mixing unit.
H
Hybrid system
A heating system with two different heat sources, most often a heat pump and a gas boiler. Depending on the outdoor temperature or other set criteria, the controller chooses which source heats, or runs both together. More about such systems on the page “Hybrid solutions”.
Hydraulic separator (low-loss header)
A vertical tubular vessel that hydraulically separates the boiler circuit from the consumer circuits (radiators, underfloor heating, hot water cylinder). This way the pump of each circuit works independently and does not interfere with the others. A hydraulic separator is used in systems with several circuits or several heat sources; some models also separate air and sludge.
I
Inhibitor
A chemical additive put into the heating system water to slow corrosion of metal parts and the build-up of deposits. Whether to use an additive, which one and at what concentration is specified by the boiler manufacturer. After flushing the system or topping up a larger amount of water, it is recommended that a specialist checks whether there is enough additive in the system.
Expansion vessel
A vessel with a rubber membrane, with system water on one side and a cushion of pressurised gas on the other. It absorbs the excess volume of water as it warms and expands, so the system pressure varies only slightly. If the vessel’s gas cushion is lost, the pressure rises sharply as the system heats and drops when it cools; more in the article “Boiler pressure”.
J
Ionisation electrode
A flame detection electrode in the burner. A small ionisation current flows through the flame, and from it the control board determines whether the flame is burning; if there is no current, the gas valve closes and the boiler locks out with an error code. In some boilers the same part also works as the ignition electrode.
K
Limescale
Hard mineral deposits that settle from hard water on heated surfaces. In a combi boiler they most often build up in the secondary (hot water) heat exchanger: the hot water flow weakens and its temperature fluctuates. Scale is removed by chemical flushing or by replacing the heat exchanger.
Room thermostat
A device that measures the air temperature in a room and switches the boiler’s heating on or off according to the set value. Simpler thermostats only switch the boiler on and off, while modulating ones (for example, using the OpenTherm protocol) pass the required output or temperature to the boiler. It is recommended to replace the batteries of wireless thermostats before the heating season.
Chimney liner
A stainless steel or plastic pipe fitted into an existing masonry chimney. It protects the chimney from moisture and condensate, and its diameter and material are chosen to suit the connected boiler. A condensing boiler needs a sealed liner resistant to condensate.
Error code
A combination of letters and numbers by which the boiler display reports a fault or warning. The same code means different things on boilers from different manufacturers, so it must always be checked against the specific boiler’s manual. The most common codes are explained in the article “Boiler error codes” and in the error code list.
Coaxial flue
A “pipe in a pipe” flue: flue gases leave the boiler through the inner pipe, while combustion air is drawn in from outside through the gap between the inner and outer pipes. Such a flue is used for room-sealed boilers and is usually taken out through a wall or roof. Its terminal outside must be clear.
Combination (combi) boiler
This term is used in two senses. For gas boilers it often refers to a combi boiler, which heats the home and makes hot water on demand without a separate tank. For solid fuel boilers, a combination boiler is one that can burn several types of fuel, for example logs and pellets. If the term appears in a quote, it is worth checking which meaning is intended.
Condensing boiler
A gas boiler that additionally uses the heat released when the water vapour in the flue gases condenses. Condensation takes place when the heat exchanger is cooled by the returning heating water below the dew point of the flue gases, which for natural gas flue gases is about 55 °C. That is why the benefit of condensation is greatest when the heating system runs at a lower temperature. A condensing boiler needs a condensate drain to the sewer.
Condensate
Water that forms in a condensing boiler when the flue gases cool. It is slightly acidic, so it is drained to the sewer through a trap and a dedicated pipe. A condensate pipe running outside can freeze in cold weather and stop the boiler; more in the article “Boiler not heating”.
Condensate trap
A part of a condensing boiler with a water seal, through which condensate drains while flue gases cannot get into the room. The trap must be filled with water; it is cleaned during annual servicing because deposits build up in it.
L
Outdoor temperature sensor
A sensor mounted on a north-facing or other shaded wall of the building that passes the outdoor air temperature to the boiler. From it and the set heating curve, the boiler chooses the heating water temperature itself: on a colder day it supplies warmer water, on a warmer day cooler water.
M
Mixing unit
A unit with a mixing valve that blends cooled return water into the hot supply water and so keeps a lower temperature in a separate circuit, most often underfloor heating. It usually also has its own circulation pump.
Pressure gauge
A device showing the water pressure in the heating system. It can be a dial gauge or digital, shown on the boiler display. Pressure is shown in bar or megapascals: 1 bar equals 0,1 MPa; more in the article “Boiler pressure”.
Modulating burner and modulation
A modulating burner can smoothly vary the flame size, and so the boiler output, within a certain range between minimum and maximum output. Modulation lets the boiler run longer at lower output instead of frequently switching on and off at full power. The modulation range is given in the boiler’s technical data.
N
NTC sensor
A temperature sensor (thermistor) whose electrical resistance falls as the temperature rises. In a boiler such sensors measure the temperature of the heating supply and return water and of the hot water. If a sensor fails or its wire breaks, the boiler usually shows an error code.
Bleeding (air removal)
Releasing trapped air from radiators and the heating system. Air hinders water circulation, so the radiator stays cold at the top and you hear bubbling in the system. Releasing air lowers the system pressure, so it needs to be checked after bleeding; the steps are described in the guide to bleeding radiators.
P
Commissioning
The first start-up of the boiler after installation or a longer shutdown, carried out by a specialist. It includes checking the tightness of gas connections, system pressure and air removal, carrying out a combustion analysis and setting the boiler parameters. Some manufacturers require for the warranty that commissioning be done by their authorised specialist; the exact conditions are in the boiler’s warranty card.
Filling valve
A valve through which mains water is let into the heating system when the pressure drops too low. It is usually at the bottom of the boiler or next to it; the system is filled while cold, watching the pressure gauge. After topping up, close the valve fully, because pressure can rise by itself through a leaky valve.
Preventive inspection
Periodic boiler inspection and servicing, which manufacturers say should be done every year. It includes a combustion analysis, cleaning of the boiler and condensate trap, and checks of the expansion vessel, safety devices and gas part tightness. More in the article “Annual boiler servicing”.
S
System flushing
Cleaning the heating system pipes and radiators of sludge, rust and other deposits using flushing equipment and, if necessary, special solutions. Manufacturers usually require it before a new boiler is connected to an old system. More in the article “Heating system flushing”.
System pressure (bar)
The water pressure in a closed heating system, shown on the pressure gauge. For most domestic boilers the cold system pressure should be between 1 and 2 bar, and the pressure of a warmed-up system is slightly higher. The exact limits are given in the boiler manual; more in the article “Boiler pressure”.
Carbon monoxide (CO)
A colourless, odourless poisonous gas that forms when fuel burns incompletely. It appears when combustion is disrupted, the flue is blocked or there is not enough combustion air. People cannot sense carbon monoxide, so only a detector or measuring instrument can detect it; more in the article “Carbon monoxide and gas safety”.
Carbon monoxide (CO) detector
A device that gives an audible warning when the level of carbon monoxide in the air rises. It is recommended to choose a detector that complies with EN 50291 and to mount it according to the detector manufacturer’s instructions in the room with the boiler and near the bedrooms. A smoke detector does not detect carbon monoxide.
Flow switch
A combi boiler sensor that detects that a hot water tap has been opened and switches the boiler to hot water mode. If it becomes dirty or fails, the boiler may not start when a tap is opened, or may make hot water intermittently.
Š
Heating curve
A boiler or controller setting that defines what heating water temperature to supply at a given outdoor temperature. It is used together with an outdoor temperature sensor. A well-chosen curve lets the boiler run at a lower temperature when it is not cold outside.
Heat exchanger (primary and secondary)
A heat exchanger is a device in which heat passes from one medium to another without mixing them. In the primary heat exchanger, the heat of the flue gases is transferred to the heating system water. In a combi boiler, the secondary (plate) heat exchanger transfers heat from the heating water to the mains water that flows to the hot water taps; more on the page “Heat exchanger flushing”.
Heat pump
A device that uses electricity to move heat from the outdoor air, ground or water into the building’s heating system and hot water tank. Its efficiency is higher when the heating system can work with a lower water temperature, for example underfloor heating. A comparison with a gas boiler is in the article “Heat pump or gas boiler”.
T
Thermostatic radiator valve head
A radiator valve head that, according to its set position, limits the water flow through the radiator by itself and so maintains the chosen room temperature. A head left closed for a long time can stick, so before the season it is recommended to open it fully and check that the radiator heats up.
Three-way valve
A valve with three connections that directs the water heated by the boiler either to the heating system or to hot water production (the secondary heat exchanger or a hot water cylinder). In combi boilers it is built into the boiler. If the valve malfunctions, the radiators may heat up while hot water is being made, or, conversely, no hot water is made.
U
Room-sealed (“turbo”) boiler
A boiler whose combustion chamber is sealed off from the room. A fan draws combustion air from outside and pushes the flue gases out through the same, usually coaxial flue. In everyday speech such boilers are called “turbo” boilers; modern condensing boilers also have a sealed combustion chamber.
Ignition electrode
A burner electrode that ignites the gas and air mixture with a high-voltage spark when the boiler starts heating. A worn, burnt or incorrectly positioned electrode can be the reason why the boiler does not light and locks out. It is checked and replaced by a specialist.
V
Control board
The boiler’s electronic control unit, which uses sensor data and user settings to control the burner, gas valve, pump, fan and three-way valve. It also monitors the safety devices and, when it detects a fault, shows an error code. A board fault is identified by a specialist during diagnostics, because the same symptoms are often caused by sensors or wiring.
Summer and winter mode
The boiler’s operating modes. In summer mode the boiler only makes hot water; in winter mode it both heats the home and makes hot water. In autumn, before the heating season, the boiler should be switched to winter mode.
Frequently asked questions
What is the difference between a condensing and an open-flue boiler?
An open-flue boiler takes combustion air from the room, and the flue gases leave by natural draught. A condensing boiler has a sealed combustion chamber and additionally uses the heat released when the water vapour in the flue gases condenses.
What does a combi or combination boiler mean?
For gas boilers, it is a boiler that heats the home and makes hot water on demand without a separate tank. For solid fuel boilers, a combination boiler is one that can burn several types of fuel.
Which boiler tasks can I do myself?
The user’s tasks are described in the boiler’s user manual: checking and topping up the pressure, bleeding radiators, mode and temperature settings, resetting with the button. Do not open the boiler casing, and leave the gas and combustion parts to a specialist.
Does a smoke detector detect carbon monoxide?
No. A smoke detector responds to smoke; a separate carbon monoxide (CO) detector is needed to detect carbon monoxide.
Why are there different explanations for the same error code?
Each manufacturer defines its error codes in its own way. The same code can mean different faults on boilers from different manufacturers, so always check it against your boiler’s manual.
Need a technician?
We have worked across Lithuania since 2016 and arrive with spare parts. Describe the situation or give us a call.
Our services
Sources
- Vaillant ecoTEC plus VU/VUW, installation and maintenance instructions, doc. 0020308118_05 (2023-05-31): safety section 1.3, pressure 9.7, water quality 9.3, maintenance table (Appendix B)
- Commission Delegated Regulation (EU) No 811/2013 on the energy labelling of space heaters
- Commission Regulation (EU) No 813/2013 on ecodesign requirements for space heaters, Annex II
- Pasvalys District Municipality, "Stand-alone smoke and carbon monoxide detectors can protect our lives"
This article is general information. Always follow the manual of your own boiler, and leave work on gas and combustion components to a certified specialist.