Pereiti prie turinio

Mon–Fri 8–18

We work across Lithuania
Advice

Heat pump or gas boiler: which suits your home

Updated 10 November 2026 · 6 min read · Prepared by the technicians of Visų katilų remontas

When an old boiler is being replaced, the question comes up more and more often: is it time to give up gas and choose a heat pump? The answer depends not on fashion or on a neighbour's experience but on your house: how well it is insulated, what radiators it has, whether gas is connected and how much space there is outside. Both heating methods can be good if chosen properly, and both can disappoint if not. In this article we explain how they differ, how to compare the costs yourself and what state funding is currently available for heat pumps.

In brief

  • A gas boiler gets heat by burning gas; a heat pump uses electricity to move heat from the outdoor air, the ground or water.
  • A heat pump is most efficient when the house is well insulated and cooler water is enough for heating, e.g. with underfloor heating.
  • You can compare heating costs yourself: divide the energy price by the efficiency of the appliance.
  • The Lithuanian Energy Agency reimburses up to 50 % of the cost of a heat pump at fixed rates, but the application is submitted only after the unit has been installed.
  • Gas and hybrid appliances are not funded under this programme.

How each of them works

A gas condensing boiler burns gas and transfers the heat to the heating water. A condensing boiler also cools the flue gases and recovers heat from the water vapour in them, so more heat is obtained from the same amount of gas than in old boilers.

A heat pump does not produce heat by burning. It works like a refrigerator in reverse: a compressor driven by electricity takes heat from the outdoor air, the ground or groundwater and transfers it to the home's heating system. Because most of the heat is taken from the environment, one kilowatt-hour of electricity yields several kilowatt-hours of heat. Exactly how many is shown by the seasonal coefficient of performance, SCOP.

Gas boilerHeat pump heat gasto the radiators heat is produced by burning fuel heat air + electricityto the floor, radiators heat is moved in from outdoors
A gas boiler gets heat by combustion; a heat pump moves it from the environment.

There are several types of heat pump. For homes the usual choice is air-to-water: the outdoor unit takes heat from the air, and the indoor unit heats the water for the radiators or underfloor heating. A ground-to-water (geothermal) pump takes heat from the ground through boreholes or pipes laid in the soil. It costs more to install but depends less on the outdoor temperature. An air-to-air pump heats the room air directly, like an air conditioner, and has no water system.

What the EU requirements say

The same EU Regulation 813/2013 sets the minimum seasonal space heating efficiency for both boilers and heat pumps. It is calculated on a primary energy basis, so the figures can be compared with each other:

  • gas boilers (from 26 September 2015): at least 86 %;
  • heat pumps (from 26 September 2017): at least 110 %;
  • low-temperature heat pumps: at least 125 %.

These are minimum requirements. The efficiency of a particular appliance is given on its energy label and in the product data sheet. A heat pump label shows efficiency for two cases: when the heating water is at 35 °C (suitable for underfloor heating) and at 55 °C (more often needed for radiators). The difference between them is usually large, and this is the most important thing to understand when choosing.

The key point: what water temperature your house needs

A heat pump works more efficiently the smaller the difference between the temperature it takes heat from and the temperature it has to reach. It is therefore best suited to houses where cooler water is enough for heating:

  • a well-insulated or renovated house that needs little heat;
  • underfloor heating or large-area, low-temperature radiators;
  • airtight windows and heat recovery ventilation, which reduce heat losses.

An old, poorly insulated house with small radiators often needs hot water in cold weather. Here a heat pump will run at lower efficiency, and in the coldest weather electric backup heating may have to come on. This does not mean a heat pump is unsuitable, but such a house needs a careful calculation, and sometimes it is worth insulating the house or fitting larger radiators first.

A gas condensing boiler is the simpler solution for such houses: it easily produces hot water for radiators and takes up little space. That said, it too is most economical when the return water is cooler than about 55 °C, because the vapour in the flue gases then condenses.

Comparison

Gas condensing boilerAir-to-water heat pump
EnergyNatural gas or LPGElectricity and heat from outdoor air
What is neededA gas connection or tank, a flue, a condensate drainSpace for the outdoor unit, sufficient electricity supply capacity
Best suited toAny house, including those with ordinary radiatorsAn insulated house with underfloor or low-temperature heating
SpaceWall-hung, takes up little spaceOutdoor unit and indoor unit, often a hot water cylinder
NoiseQuiet, runs indoorsThe outdoor unit can be heard; its location must be chosen with the neighbours in mind
MaintenanceYearly: combustion measurement, cleaningRegularly: outdoor unit cleaning, system check
LEA fundingNot fundedUp to 50 % at fixed rates

Which is cheaper: compare for your home

Whether a heat pump will be cheaper depends on three things: energy prices, how much heat your house needs and what water temperature the radiators need. With underfloor heating a heat pump produces more heat from one kWh of electricity than with hot radiators, so the same heat pump can be considerably cheaper than gas in one house and not in another.

Enter in the calculator how much gas you use per year. From that we will work out how much heat your house needs and compare what it would cost with a new condensing boiler and with a heat pump.

Calculator: which is cheaper for heating your home

Answer three questions. We will compare the yearly cost of heating with a new gas condensing boiler and with a heat pump.

m³
Check your annual gas bill or your supplier's self-service portal. If you also use gas for hot water, change nothing – the calculator will compare all the heat.
What boiler do you have now?
How is the house heated?
New gas condensing boiler

Air-to-water heat pump

Which prices are used? Change

Pre-filled are the official average prices for Lithuanian households in the first half of 2026 published by Eurostat, including VAT, distribution and fixed components: gas – 0,0629 €/kWh (for homes heated with gas), electricity – for homes using 5 000–15 000 kWh per year. We update them automatically when Eurostat publishes new data. If the prices in your contract are different, enter your own.

We also assume: 1 m³ of gas – 10,82 kWh of energy; seasonal efficiency of a condensing boiler 92 %, of an old conventional one – 75 %; from 1 kWh of electricity a heat pump produces over the season 4,0 kWh of heat with underfloor heating, 3,0 – with radiators and 2,5 – when the radiators need hot water.

Only the energy cost is compared. Equipment and installation costs, maintenance and funding are not included. The actual efficiency of a heat pump depends on the model and the house, so this is a guide, not a quote.

When deciding, add the other factors as well: the upfront cost of equipment and installation, maintenance costs and funding. If the house already has a gas connection and a working system, and the heat demand is high, the calculation may give a different result than for a new, well-insulated house.

Or perhaps both together?

In a hybrid system the heat pump provides heating for most of the season, when it is not very cold outside, and the gas boiler comes on in the coldest weather or when a lot of hot water is needed. This solution can suit houses that cannot be insulated straight away or that already have a good gas boiler. However, hybrid appliances are not funded under the LEA boiler replacement programme. You will find more about such solutions on the "Hybrid solutions" page.

State funding for a heat pump

Funding for replacing old boilers, often still called APVA funding, is currently administered by the Lithuanian Energy Agency (LEA). The main conditions according to the information published on the LEA website (as of November 2026):

  • For whom: private individuals who own a home that is not connected to district heating.
  • What to replace: an inefficient biomass or fossil fuel boiler that heated a water-based system, or a stove or fireplace that heated only the air. Whether your old boiler meets the conditions is best checked with the LEA.
  • What is funded: new air-to-water, water-to-water and ground-to-water heat pumps, class 5 biomass boilers, and air-to-air heat pumps only when replacing systems that heated the air. Gas and hybrid appliances are not funded.
  • How much: up to 50 % of eligible costs. These are calculated from the output of the appliance and the rate per kilowatt set by the LEA.
  • When to apply: only after the new appliance has been installed. Applications submitted before installation are not considered. Appliances installed from 26 July 2023 are funded.
  • Calls: announced on the first working day of each quarter. The programme runs until 2029.
  • Obligation: the appliance must be kept for 5 years after the end of the funding.

For example, for a 8 kW air-to-water heat pump without an integrated water heater the LEA rate is 591,38 €/kW including VAT: 8 × 591,38 = 4 731,04 €, and the funding would be up to half of that amount, i.e. up to 2 365,52 €. Calculate it for your appliance below. The rates may change, so before deciding check the current ones on the LEA website.

Calculator: funding at LEA rates

Rates from the LEA website (November 2026), including VAT. Funding is granted only if all programme conditions are met, and the application is submitted after the appliance has been installed. The final amount is set by the LEA.

For the application with a payment request you will need a VAT invoice in your name, a signed installation handover report stating the address and output of the appliance, technical documents confirming the output and the requirements, and photos of the new appliance and its label. So ask the installer for these documents straight away.

How to decide

  1. Assess the house: insulation, type of heating (underfloor or radiators), heat demand.
  2. Find out the water temperature needed in cold weather: if 35–45 °C is enough, a heat pump has a clear advantage.
  3. Calculate the heating cost using your own gas and electricity prices.
  4. Add equipment, installation and funding and compare the total.
  5. Consult a specialist who will inspect the house on site.

Frequently asked questions

Does a heat pump provide heating in severe frost?

It does, but its efficiency is lower then. How much lower is stated by the manufacturer. The system often also has an electric backup heater that comes on in the coldest weather.

Is a heat pump suitable with old radiators?

It can be, if the house is sufficiently insulated and the radiators are large enough. When the radiators need hot water, the heat pump's efficiency drops, so a careful calculation is needed in that case.

Is funding available for a gas boiler?

Gas and hybrid appliances are not funded under the LEA boiler replacement programme. Heat pumps and class 5 biomass boilers are funded.

Can the funding application be submitted before installation?

No. Under the LEA conditions the application is submitted only after the new appliance has been installed, together with the payment request and documents.

Need a technician?

We have worked across Lithuania since 2016 and arrive with spare parts. Describe the situation or give us a call.

Tips: Heat pump or boiler

Write the boiler manufacturer and model or attach a photo of the rating plate – we will call you and help.

+370 630 13331Request a service

Sources

  1. Lithuanian Energy Agency: Inefficient boiler replacement programme (conditions, rates, calls)
  2. Lithuanian Energy Agency: boiler replacement FAQ
  3. Commission Regulation (EU) No 813/2013, Annex II (efficiency requirements for boilers and heat pumps)
  4. Commission Delegated Regulation (EU) No 811/2013 on the energy labelling of space heaters

This article is general information. Always follow the manual of your own boiler, and leave work on gas and combustion components to a certified specialist.

More tips

CallRegister