Connecting a gas boiler to the heating system: what it involves
Hanging a boiler on the wall is the smallest part of the job. Connecting a boiler means linking it to several systems in your home: the heating pipework, the water supply, the gas pipeline, the flue, the drain and the electrics, and then commissioning and setting it up so that it suits your particular house. In this article we explain what the connection consists of, what layouts are used, what you can prepare yourself and why the gas part must not be connected on your own.
In brief
- Connection covers the heating circuit, hot water (for a combi boiler), gas, flue, condensate drain, electrics and commissioning.
- A filter is fitted on the return pipe before the boiler, and the system must have an expansion vessel and a safety valve.
- The gas part is connected according to the design only by a certified gas specialist. Whether a new design is needed depends on the work.
- Underfloor heating or two boilers often need a hydraulic separator or a mixing valve. The technician chooses the layout.
- The first start-up is carried out by a qualified specialist: they measure combustion and set the boiler up for the house.
What connecting a boiler consists of
A gas boiler is the heart of the heating system, but on its own it heats nothing. For it to work safely and economically, several separate systems are connected to it. Each has its own requirements, and each is worth understanding when you compare quotes or talk to a technician.
- Heating circuit: flow and return pipes with isolating valves, a filter, an expansion vessel and a safety valve.
- Filling: a filling valve through which the system is filled with water and later topped up.
- Hot water circuit: cold water inlet and hot water outlet for a combi boiler, or a hot water cylinder connection.
- Gas: connection to the internal gas pipeline via a gas valve. This work is done only by a certified gas specialist.
- Flue and condensate: flue gas discharge and combustion air supply, condensate drain to the sewer.
- Electrics and controls: power supply, room thermostat or outdoor temperature sensor.
- Commissioning and settings: leak test, combustion measurement, setting the output and temperatures.
Heating circuit: flow and return pipes
From the boiler, hot water flows through the flow pipe to the radiators or underfloor heating and, once cooled, comes back through the return pipe. Both pipes are connected to the boiler via isolating valves. They allow the boiler to be isolated for maintenance or repair without draining the whole system.
A filter, usually a magnetic one, or a dirt separator is fitted on the return pipe before the boiler. It traps rust particles and sludge before they reach the pump and the heat exchanger. If the boiler is being connected to an old system, the system must be flushed first: manufacturers list this as an installation step. We write more about this in the article “Heating system flushing”.
The expansion vessel absorbs the excess water as it heats up and expands. In most wall-hung boilers it is built in, but a larger system, for example one with underfloor heating or many radiators, may need an additional external vessel. The technician sizes the vessel according to the system's water volume. Why this matters for pressure is explained in the article “Boiler pressure”.
The safety valve releases water if the pressure rises too high. Its discharge pipe must be routed to the drain so that you can see if the valve is dripping. In most wall-hung boilers the safety valve and the circulation pump are already inside the boiler.
Filling, bleeding and leak test
Once the pipes are connected, the system is filled with water through the filling valve. It is filled slowly while watching the pressure gauge, and air is released from the radiators and the boiler. Then all joints are checked for leaks. Manufacturers also specify water quality requirements, so in some cases treated water or additives approved by the manufacturer are used to fill the system.
In the first weeks dissolved air is still released from the water, so you may need to top up the pressure several times. How to do it yourself and what the pressure should be is described in the “Boiler pressure” article, section “How to fill the heating system”.
Hot water circuit
A combi boiler heats water as it flows: a cold water inlet and a hot water outlet to the taps are connected to it, both with isolating valves. If the mains water is hard or dirty, it is worth fitting a filter before the boiler, because the secondary heat exchanger scales up faster.
A heat-only boiler only heats the house, and hot water is prepared in a separate cylinder. The cylinder is then connected as a separate heating circuit with its own control, for example via a three-way valve and a cylinder temperature sensor. Whether these are already in the boiler or fitted separately depends on the model.
Gas connection: certified specialist only
In Lithuania gas appliances are connected and commissioned by certified specialists. The boiler is connected to the internal gas pipeline via a gas valve according to the gas system design, and the joints are leak-tested after connection. Whether your case needs a new design and handover of the work to the gas distribution operator depends on what changes: whether the boiler is installed in a new location, the gas pipework is replaced or extended, the output increases, or the flue gas discharge method changes. A specialist assesses this during the site visit. We do this work as part of our gas and gas pipeline works service.
Do not connect or dismantle the gas part yourself. This is required by law, and the reason is simple: a leaking gas joint or incorrectly set combustion creates a risk of fire, explosion and carbon monoxide poisoning. If you smell gas, do not switch electrical switches on or off and do not light a flame. Open the windows, close the gas valve if possible, go outside and from there call the gas emergency service on 1804 or 112.
Flue and condensate drain
A modern gas boiler is most often a condensing boiler with a sealed combustion chamber. It needs a condensate-resistant flue, often a coaxial one: flue gases leave through the inner pipe and combustion air comes in through the outer one. The flue is installed according to the boiler manufacturer's requirements, with the slope and length they specify. An old masonry chimney is only suitable with a special liner. We write more about this in the article “Boiler replacement from A to Z”.
A condensing boiler produces water, which is drained through a trap into the sewer. So think in advance whether there is a drain connection near the boiler location. If the condensate pipe runs through a cold room or outdoors, it is insulated so that it does not freeze in winter.
Electrics and controls
The boiler needs electricity for its controls, pump and fan. Manufacturers specify connecting it to an earthed socket or a separate circuit with a switch. A room thermostat or an outdoor temperature sensor is often connected to the boiler so that it works as much as the house needs, not at one fixed temperature.
Commissioning and settings
The first start-up is a separate job. Manufacturers' instructions state that it is carried out by a service specialist or another authorised, qualified person. During commissioning the gas pressure and tightness are checked, combustion is measured, and the flue type is set in the boiler. Then the boiler is adapted to the house:
- heating output is limited to what the house needs, so that the boiler does not switch on and off too often for no reason;
- flow temperature or heating curve is set depending on whether the house is heated by radiators or underfloor heating;
- pump mode and hot water temperature are chosen to suit the system and your habits.
A commissioning report or checklist is completed, which you will need for the warranty. Why incorrect settings make a boiler switch on too often is explained in the article “Boiler switches on and off too often”.
Most common connection layouts
The simplest layout is a single one: the boiler connected directly to the radiators. But in many homes the system is more complex, and then additional assemblies appear between the boiler and the heating circuits.
| System | How it is usually connected | Worth knowing |
|---|---|---|
| Radiators only | Boiler directly to the radiator circuit | The boiler's own pump is enough if the system is small and balanced. |
| Underfloor heating only | Boiler with a low flow temperature or via a mixing unit | Floors need a lower temperature than radiators. This suits a condensing boiler. |
| Radiators and underfloor | Via a hydraulic separator or a manifold with several circuits | Each circuit has its own pump, and the underfloor circuit often has a mixing valve. |
| Gas and solid fuel boiler | Via a hydraulic separator or buffer tank, with a mixing valve in the solid fuel boiler circuit | A dedicated solution is needed so that the boilers do not interfere with each other and are protected. |
Hydraulic separator
A hydraulic separator, also called a low-loss header, separates the boiler circuit from the heating circuits. When the system has several pumps, for example for radiators and underfloor heating, without it the pumps can interfere with each other and the boiler can get too little or too much flow. The separator lets each circuit work in its own mode.
Four-way mixing valve
A four-way mixing valve mixes the hot flow water with the return water. This way water of the required temperature flows into the system, and water that is too cold does not return to the boiler. It is most often fitted in the solid fuel boiler circuit, where cold return water encourages tar and condensate build-up in the firebox. For a condensing gas boiler, on the contrary, cool return water is beneficial, so when connecting both boilers the layout is chosen so that each gets water at a suitable temperature. For such a system the solution is chosen by a technician or designer according to both boilers' instructions.
What you can prepare before the technician arrives
- A place for the boiler: a free wall or room with access for maintenance. Clear away items around the old boiler and pipes.
- Documents: any existing gas system design or ESO documents, and the new boiler's manual and warranty card if you are buying the boiler yourself.
- Information about the system: how many floors, radiators or underfloor heating, whether there is a hot water cylinder, whether the house has been renovated, which rooms used to be cool.
- Photos: of the boiler location, existing connections, chimney or flue. They help prepare a quote even before the site visit.
- Questions about drainage and electrics: whether there is a drain connection nearby for the condensate and an earthed socket.
If you are replacing a boiler rather than installing a new one, also read the article “When to replace a gas boiler”: it describes how a new boiler is chosen.
Why you should not connect a boiler yourself
Connecting heating pipes looks simple, but connecting a boiler is one job whose parts are interlinked. The law allows gas connection and commissioning to be done only by certified specialists. Manufacturers often link the warranty to the boiler having been installed and commissioned by a qualified specialist who completed the commissioning documents. And poor hydraulics, for example without a filter, with an undersized expansion vessel or with several pumps connected without thought, later show up as falling pressure, noise and frequent faults.
What you can do yourself once the boiler is running: watch the pressure, top up the system and bleed air from the radiators. How this is done is described in the article “Boiler pressure”.
How much connection costs
There is no single price, because the scope of work varies greatly: whether the boiler is replaced in the same place or installed in a new one, whether a new flue, gas pipework, design, system flushing, an external expansion vessel or a hydraulic separator is needed. We give an exact price after inspecting the site. We describe the work on the “Gas boiler installation” page, and you can request a quote via the installation enquiry form.
Frequently asked questions
How do you connect a gas boiler to the heating system?
The boiler is connected to the heating flow and return pipes via isolating valves, a filter is fitted on the return pipe, and the system must have an expansion vessel and a safety valve. The water supply (for a combi boiler), flue, condensate drain and electrics are also connected. The gas is connected according to the design by a certified specialist, who also commissions the boiler.
Can I connect a gas boiler myself?
Not the gas part: gas appliances are connected and commissioned only by certified specialists, and manufacturers often link the warranty to commissioning by a qualified specialist. You can prepare the location, gather the documents and later keep an eye on the pressure.
How much does connecting a gas boiler cost?
It depends on the work: whether the boiler is replaced in the same place, and whether a new flue, gas pipework, design, system flushing or extra assemblies are needed. We give an exact price after inspecting the site. You can request a quote via the installation enquiry form.
What is a four-way valve for in a boiler connection layout?
It mixes flow and return water so that water of the required temperature flows into the system and water that is too cold does not return to the boiler. It is most often fitted in the solid fuel boiler circuit. When connecting a gas and a solid fuel boiler, the layout is chosen by a technician according to both boilers' instructions.
Do I need a hydraulic separator?
When the system has several circuits with their own pumps, for example radiators and underfloor heating, or two boilers, a separator is often needed. A small radiator-only system usually does not need one. The technician assesses this during the site visit.
How much gas does a gas boiler use?
It depends on the house's heat loss, the weather, the desired temperature, the amount of hot water and the boiler settings. The manual states the maximum hourly consumption when the boiler runs at full output, but over a season it mostly runs at lower output. A condensing boiler runs more economically with a lower return water temperature.
Need a technician?
We have worked across Lithuania since 2016 and arrive with spare parts. Describe the situation or give us a call.
Our services
Sources
- Vaillant ecoTEC plus VU/VUW, installation and maintenance instructions, doc. 0020308118_05 (2023-05-31): installation, system flushing, water quality, commissioning
- Immergas Victrix Tera V2 24-35 Plus EU, user and installation manual, doc. 1.047821ENG
- Baxi Luna Duo-tec E, operating and installation instructions, doc. 7720148 (01-10/18)
This article is general information. Always follow the manual of your own boiler, and leave work on gas and combustion components to a certified specialist.