Water under the boiler: where it drips from and what to do
A puddle under the boiler or drops on the pipes are always worrying. Sometimes it is just condensate or a slightly leaking joint, but sometimes the boiler is signalling excessive pressure or an internal leak. First it is important to stop the damage safely and find out where the water is coming from.
In brief
- If water is dripping onto the boiler’s electrical parts or socket, switch the boiler off only if you can do so without wet hands and without standing in water.
- Put a container underneath, take a photo of where it drips and look at the pressure gauge.
- The safety valve drips when the pressure is too high: usually the expansion vessel or a filling valve that is not fully closed is to blame.
- Do not open the boiler casing yourself.
- If you smell gas, do not switch anything on or off, go outside and call 1804 or 112.
First: stop the damage
- Electricity. If water is running onto the boiler, its socket or cables, switch the boiler off at its switch or the fuse box. Do this only when you are standing on a dry surface with dry hands. If you cannot reach it safely, switch off the whole flat or house at the fuse box.
- Container. Put a container or towel under the drip.
- Photo. Take a photo of where it drips and of the pressure gauge reading. This helps the technician a lot.
Safety valve dripping
At the bottom of the boiler there is a safety valve with a pipe. It opens and releases water when the system pressure gets too high. This is not a fault but a safety device, yet it shows that something is wrong. Look at the pressure gauge: if the pressure is high, these are the most common causes.
- Filling valve not fully closed or letting water through. The system then slowly fills from the mains and the pressure rises. Check that the filling valve is closed all the way.
- Expansion vessel. Heated water expands and the expansion vessel absorbs the excess. If the vessel has lost its air pressure or the membrane has burst, the pressure rises sharply while the boiler is running. The vessel must be checked and recharged by a technician.
- System overfilled. If you recently topped up the system, you may have added too much. What the pressure should look like is described in the article “Boiler pressure”.
If the safety valve has opened several times, it may no longer close tightly and drip constantly. It then needs replacing.
Condensate pipe dripping
A condensing boiler produces condensate while running, which is led through a siphon and pipe to the drain. If water drips from a joint of this pipe or from the siphon, the pipe may be blocked, disconnected or frozen outside. Condensate is slightly acidic, so wipe up the puddle and call a technician to fix the drain. In winter a frozen pipe can be carefully thawed as described in the article “Boiler not heating”.
A joint or pipe under the boiler is dripping
Under the boiler are the heating flow and return pipes and the cold and hot water pipes, with joints and valves. If a joint is dripping, it needs tightening or a new seal. Before that the technician closes the relevant valves and, if needed, lowers the pressure. Do not take joints apart yourself: hot water can scald, and gas pipe joints must not be touched.
Water coming from inside the boiler
If water is dripping from the boiler casing itself, the heat exchanger, pump, diverter valve or internal joints may be leaking. There are electrical and gas parts inside, so do not open the casing. Switch the boiler off (safely, as described above), close the filling valve if it is open, and call a technician.
If you smell gas, do not switch any electrical switches on or off and do not light a flame. Open the windows, close the gas valve if you can, go outside and from there call the gas emergency service on 1804 or 112.
When to call a technician
- water is coming from inside the boiler;
- the safety valve drips repeatedly or constantly;
- the pressure rises while the boiler is running or keeps dropping;
- a joint is dripping that you cannot reach or tighten;
- water has got onto electrical parts.
When you call, tell us the boiler model, where it drips and what the pressure gauge shows. A photo speeds up the work a lot.
Frequently asked questions
Why is the boiler safety valve dripping?
The valve releases water when the pressure is too high. The most common causes are a filling valve that is not fully closed, an expansion vessel without air pressure or an overfilled system.
Is water under the boiler dangerous?
The water itself is usually not dangerous, but if it has got onto electrical parts, the boiler must be switched off safely. If water is coming from inside the boiler, call a technician.
Water is dripping from the condensate pipe. Is that normal?
Condensate should flow through the pipe to the drain, not drip from the joints. If a joint or the siphon is dripping, the pipe may be blocked or disconnected. A technician will fix it.
Can I keep using the boiler if it drips a little?
If only an external joint or the condensate pipe is dripping and the water does not reach electrical parts, it is usually possible until the technician’s visit, with a container underneath. If water is coming from inside the boiler or onto electrical parts, switch the boiler off.