Boiler error codes: what they say and what to do

Updated 10 November 2026 · 6 min read · Prepared by the technicians of Visų katilų remontas

A boiler cannot ring you up and tell you what is wrong with it. Instead it has a language of its own: a short combination of letters and numbers on the display. F.28, E133, 227, 10 – at first glance it looks like a cipher, but behind every code there is a very specific message set out in the manufacturer's manual. We explain how to read this language, which codes you can deal with yourself and when it is better not to press the button again but to call a technician.

In brief

  • An error code tells you which boiler safety device or sensor the fault has affected, but not always the cause itself.
  • Some codes are only warnings, others switch the burner off, and some require the reset button to be pressed.
  • The number of resets is limited; Immergas and Baxi, for example, allow 5 attempts in a row.
  • There are usually two things you can deal with yourself: low pressure and a closed gas valve.
  • If the code keeps coming back, do not keep resetting. Write it down and call a technician.

What an error code really means

A modern boiler is controlled by an electronic board. It constantly monitors dozens of sensors: water pressure and temperature, the flame signal, fan speed, flue gas temperature. When one of the readings goes outside the permitted limits, the board reacts and a code appears on the display.

One thing is important to understand: the code shows what has gone wrong, but not always why. For example, a "no flame" code can mean a closed gas valve, a worn electrode, a blocked condensate drain or a gas valve fault. The manufacturers' manuals list several possible causes next to each code, and the technician checks them one by one. That is why the same code can end in a completely different repair in different homes.

F.28 error code reset pressure
An error code on the boiler display. Vaillant and Protherm codes begin with the letter F, Baxi codes with E, Bosch and Viessmann show numbers, Immergas shows two-digit numbers.

How to recognise your boiler's code

Each manufacturer writes its codes in its own way. The look of the code often lets you guess the boiler make as well:

ManufacturerWhat the code looks likeWorth knowing
VaillantF.028, F.022On the displays of older boilers the same code is shown in a shorter form, for example F.28.
ProthermF.28, F.22When there are several faults, the codes are shown alternately every 2 seconds. The technician can see the last 10 codes in the fault memory.
Bosch, Junkers, Buderus227, 1017Newer boilers show 3–4 digits. Some older ones show a two-character code, for example EA, and an additional number.
BaxiE133, E118The display often shows a symbol and a number, while in the manual the codes are marked with the letter E.
Immergas01, 10, 38The list of the last 8 faults can be viewed in the information menu.
Viessmann65, 74, 357The fault symbol is shown first; you can see the code using the arrow buttons.

If you are not sure which boiler you have, the model is given on the manufacturer's label, usually on the underside of the boiler. Explanations of all the codes we have described can be found in the list of boiler error codes, grouped by manufacturer and model.

Warning, temporary shutdown or lockout

Not every code means that the boiler has stopped. The Bosch manual even divides faults into classes, and this logic applies to almost all boilers:

WarningThe boiler keeps working but reports a deviation. Example: Bosch 1017, water pressure too low.
Temporary shutdownThe boiler stops and switches back on by itself once the cause has gone, for example when an overheated heat exchanger has cooled down.
LockoutThe boiler stays off until the reset button is pressed. This is how the boiler reacts to more serious faults, for example when the flame does not ignite.

Why does a boiler sometimes lock out and refuse to switch on by itself? This is deliberate protection. If, say, the flame fails to ignite several times in a row, unburnt gas could build up in the combustion chamber. The board therefore stops the attempts and waits for a person to decide.

How many times you can reset

The reset button, often marked "Reset" or with a curved arrow, is meant for the user, but what it can do is limited. Manufacturers state this clearly:

  • Immergas: 5 resets in a row are allowed. After that the function is blocked for at least an hour and code 08 is shown on the display.
  • Baxi: 5 reset attempts can be made, then the boiler switches off. You have to wait 15 minutes before trying again. The button has to be held for at least 2 seconds.
  • Protherm: the button is held for more than 3 seconds. If the code remains after several attempts, call the service.
  • Vaillant: if the code comes back after a reset, the boiler should not be reset again.

Our advice is simple: reset once. If the boiler stops again with the same code, the fault has not gone away by itself, and no further attempt will remove it.

What you can deal with yourself

Manufacturers' manuals leave only a few actions to the user. Everything else that involves gas, combustion and electricity is a job for a specialist. There are usually two situations you can deal with yourself.

Water pressure too low

This is probably the most common code in homes. The boiler stops because there is too little water in the system. Look at the pressure gauge and, if the pressure is lower than stated in the manual, top up the system. How to do this safely is described in the article "Boiler pressure".

ManufacturerLow pressure
VaillantF.022
ProthermF.22
Bosch1017 (warning), 207
BaxiE118
Immergas10
Viessmann74

The flame does not ignite

When the boiler tries to light the burner several times and fails, it locks out. Before calling a technician, check that the gas valve before the boiler is open and that other appliances in the house, such as the cooker, have gas. If the valve is open, reset the boiler once. If the code comes back, the cause is inside the boiler.

ManufacturerThe flame does not ignite
VaillantF.028, flame went out during operation – F.029
ProthermF.28
Bosch227
BaxiE133 (5 failed attempts)
Immergas01
Viessmann357 (insufficient gas supply)

If you smell gas, do not reset the boiler and do not operate any switches. Open the windows, close the gas valve if you can, go outside and call 112 from there.

Codes that need a technician

Most codes in the manuals are marked with one phrase: "call a certified specialist". This is not excessive caution. Such codes relate to parts the user cannot and should not check: flame monitoring, flue gas discharge, overheating protection, sensors and the board.

  • Overheating. Vaillant F.020, Immergas 02, Baxi E110, Bosch 224, Viessmann 62. The safety thermostat has tripped. The causes most often mentioned in the manuals are lack of water or circulation problems (air, a closed valve, a pump fault, the expansion vessel), as well as faults in sensors or their wiring.
  • Flame signal faults. The flame goes out during operation, or the flame signal is weak or unstable. The electrodes, the gas supply and the combustion settings are usually checked.
  • Flue and condensate codes. For example, Vaillant F.035 indicates a blocked air and flue pipe, Viessmann 176 a build-up of condensate. In winter a condensate pipe running outdoors can freeze.
  • Sensor and board codes. A disconnected or faulty temperature, pressure or flue gas sensor, a configuration error.

When you call a technician, give the exact code and the boiler model. He will then know in advance which parts may be needed and will often fix the fault in a single visit. Our technicians carry the most commonly replaced parts with them.

Write the codes down

A small habit is worth having: when the boiler shows a code, write it down with the date, even if the boiler then switched back on by itself. Sometimes a single code means nothing, but if the same code comes back every week, it is a clear sign that something is weakening. Most boilers also store a history of recent faults themselves, which the technician reviews during the annual service, but your notes also show what has been deleted or happened several months ago.

Frequently asked questions

What should I do if the boiler shows an error code?

First write down the code and the boiler model. If it is low pressure, top up the system. If the flame does not ignite, check that the gas valve is open and reset the boiler once. If the code comes back or it is a different code, call a technician.

How many times can the reset button be pressed?

Manufacturers limit this: Immergas allows 5 resets in a row, after which the function is blocked for at least an hour. Baxi allows 5 attempts, after which you have to wait 15 minutes. We advise resetting once and, if the code comes back, calling a technician.

The boiler is working again after an error. Do I need to do anything?

Write down the code and the date. A single code may mean nothing, but if it comes back, it is a sign of a fault. Mention it to the technician at the next service.

Does the same code always mean the same fault?

Not always. The code shows which safety device or sensor has reacted, and there may be several causes. For example, a "no flame" code can be caused by a closed gas valve, a worn electrode or a gas valve fault.

Are other manufacturers' codes the same?

No. Each manufacturer has its own code system, and even boilers of different generations from the same manufacturer may use different codes. Always check the manual for your boiler model.

Need a technician?

We have worked across Lithuania since 2016 and arrive with spare parts. Describe the situation or give us a call.

Tips: Error codes

Write the boiler manufacturer and model or attach a photo of the rating plate – we will call you and help.

+370 630 13331Request a service

Sources

  1. Vaillant ecoTEC plus VU/VUW, installation and maintenance instructions, doc. 0020308118_05 (2023-05-31), Appendix F "Fault codes"
  2. Protherm Gepard Condens, installation and maintenance instructions (Appendix D) and operating instructions (Appendix B), doc. 0020199149_01 and 0020199021_01
  3. Bosch Condens 2300i W, installation and maintenance instructions, doc. 6720878837 (2025/12), section 17.2
  4. Baxi Luna Duo-tec E, operating and installation instructions, doc. 7720148 (01-10/18)
  5. Immergas Victrix Tera V2 24-35 Plus EU, operating and installation instructions, doc. 1.047821ENG, section 2.5
  6. Viessmann Vitodens 100-W B1HF, B1KF, installation and maintenance instructions, doc. 6135835 FR (2021-10)

This article is general information. Always follow the manual of your own boiler, and leave work on gas and combustion components to a certified specialist.