Boiler pressure: what it should be, why it drops and what to do
In the morning the walls are cool, the radiators are cold and a code is flashing on the boiler display. Often the culprit is not an expensive component but a simple number on the pressure gauge. Pressure in a heating system is like blood pressure: while it is normal we do not notice it, but as soon as it drifts, the boiler protects itself and stops. We explain what the pressure gauge shows, what limits manufacturers specify, what you can safely do yourself and when pressure fluctuations point to a fault.
In brief
- With the system cold, the pressure should usually be between 1 and 2 bar. The exact limit is given in your boiler's manual.
- Water expands as it heats up, so the pressure in a warm system is slightly higher. This is normal.
- You can restore low pressure yourself: top up the system through the filling tap while it is cold.
- If you have to top up often, the safety valve drips or the pressure rises on its own, call a technician.
What pressure in a heating system is
A modern home heating system is sealed. The boiler, pipes and radiators form a single loop in which the same water circulates for years: the pump drives it through the boiler's heat exchanger, from there to the radiators and back. For this loop to work, there must be not only enough water in it, but the water must also be slightly compressed. That compression is what the pressure gauge shows.
Pressure is needed for a simple reason: the water has to reach the highest radiator and keep air out of the system. One bar corresponds to the pressure of a water column of roughly ten metres. So a two-storey house, where the top radiator hangs several metres above the boiler, needs slightly more pressure than a single-storey flat. The Vaillant manual states it plainly: for every metre of height above the boiler, the pressure must be increased by 0,1 bar.
Pressure is measured in bar. Some boilers show megapascals (MPa): 1 bar is 0,1 MPa, so a reading of 0,12 on the display means 1,2 bar. Older boilers have a dial gauge with coloured zones, newer ones show a number on the display, sometimes after pressing a button.
What the pressure should be
There is no single figure for all boilers, but the limits given by manufacturers are similar. For most wall-hung domestic boilers the cold-system pressure should be between 1 and 2 bar. Below is what the manuals of several boilers most common in Lithuania say.
| Boiler | Normal pressure | Worth knowing |
|---|---|---|
| Vaillant ecoTEC plus | 1,0–2,0 bar | Below 0,8 bar a warning flashes on the display. At 0,3 bar the boiler shuts down and shows F.022. The maximum permitted pressure is 2,5 bar. |
| Immergas Victrix Tera | 1,0–1,2 bar (cold system) | At around 3 bar the safety valve may open. According to the manufacturer, frequent pressure drops point to a possible leak. |
| Baxi Luna Duo-tec E | 1,0–1,5 bar (cold system) | The burner is lit only when the pressure is above 0,5 bar. Above 2,7 bar E117 is shown. |
| Viessmann Vitodens 100 | at least 1,0 bar | The pressure of a warm system must not exceed 3,0 bar. |
The most important rule: judge the pressure when the system is cold, for example in the morning or an hour after the boiler has stopped heating. A hot system always shows slightly more, and that difference is not a fault.
Why the pressure changes: heating water and the expansion vessel
Water expands when heated. Heated from 10 to 80 degrees, it takes up about 3 per cent more space. That does not seem much, but if there are a hundred litres of water in the system, heating produces about three litres that need somewhere to go. Water is almost incompressible, so without a special device the pressure would shoot up instantly.
That surplus is absorbed by the expansion vessel. In most wall-hung boilers it is built in; in larger systems it is mounted separately. Inside the vessel a rubber membrane separates two parts: water on one side, a cushion of compressed gas on the other. As the water heats up it flows into the vessel and compresses the cushion, so the pressure rises only slightly. As the water cools it returns to the system and the pressure falls again.
When the vessel's gas cushion loses its charge over time or the membrane is damaged, the vessel can no longer absorb the surplus. The pressure then rises far more as the system heats up, until the safety valve opens and releases some of the water. Once the system cools there is not enough water, the pressure drops below normal, and the cycle starts again. This "jumping" is one of the most common reasons why owners say the boiler "loses pressure by itself".
Why the pressure drops
In a leak-tight system the pressure stays stable for months on end. If it drops, water is escaping somewhere or something in the system has changed. The most common causes:
- Air has been bled. When air is bled from the radiators, water takes its place, so the pressure drops. This is normal: simply top up the system after bleeding.
- A small leak. A radiator valve, joint or thread is dripping, sometimes a pipe in the floor or wall. On hot pipes the water evaporates before it can collect, so there is often no puddle to see, only white deposits or a rust mark.
- The expansion vessel. As described above: the pressure rises sharply when the system heats up and drops once it cools.
- The safety valve. If it drips constantly or from time to time, water escapes through its discharge pipe. Check for moisture under the boiler or at the drain connection.
- A new system. In the first weeks after installation dissolved air is released from the water, so you may need to top up the pressure several times. After that it should settle.
Why the pressure rises
A slightly higher pressure in a warm system is normal. It is worth worrying if the pressure approaches 3 bar, the safety valve drips or the pressure rises even when the boiler is not heating. In that case there are three most common causes: an overfilled system, a filling tap that does not close tightly and lets mains water seep slowly into the heating system, or a faulty expansion vessel. In combi boilers a leaking internal hot water heat exchanger can cause the same thing. Some boilers report excessive pressure with a code, for example Baxi E117 or Viessmann 87.
If you have simply overfilled the system while it was cold, you can let a little water out through a radiator bleed valve into a container until the pressure returns to normal. In all other cases the cause must be identified by a technician.
How to top up the system safely
Topping up means letting mains water into the heating system through the tap provided for this purpose. Manufacturers leave this job to the user, so it is described in the user manual of every boiler. The boiler casing does not need to be removed; the tap can be reached from below or from the front.
- Wait until the system has cooled down. Only a cold system shows the true pressure.
- Find the filling tap. It is usually on the underside of the boiler, between the pipes. If the boiler has no built-in tap, the system is filled through a separate tap or a flexible hose next to the boiler. The manual shows the exact location.
- Open the tap slowly. You will hear water flowing. Keep your eyes on the pressure gauge: the pressure will rise gradually.
- Close it at the normal level. For most boilers 1,2–1,5 bar is enough, unless your manual says otherwise. Close the tap fully so that water does not keep seeping in.
- If the boiler was showing an error, reset it. Many boilers switch on by themselves once the pressure is back. Others need the reset button to be pressed, as described in the manual.
- Check again after a few hours. If there was air in the system, the pressure will drop a little more. Then top up to the normal level and note the date.
What not to do. Do not top up a hot system, do not open the boiler casing and do not dismantle gas or combustion parts. If you cannot find the filling tap or it will not turn, do not force it: call us, and a technician will explain over the phone or come out.
What the error codes mean
When the pressure drops too low, the boiler reports it with a code. Some boilers only warn and keep running, others immediately switch off the burner and pump so that the heat exchanger does not overheat without water.
| Manufacturer | Code | What it means |
|---|---|---|
| Vaillant | F.022 | No water in the boiler or the water pressure is too low. The boiler shuts down. |
| Protherm | F.22 | No water in the boiler or too little of it. Safety shutdown. |
| Immergas | 10 | Pressure in the heating system is too low. The boiler does not work until the pressure is restored. |
| Baxi | E118 | Pressure in the hydraulic circuit is too low. |
| Viessmann | 74 | System pressure is too low. The burner is locked out and the pump is switched off. |
| Bosch | 1017 | Water pressure is too low. The boiler keeps running but shows a warning. |
Explanations of all codes by manufacturer can be found in the list of boiler error codes.
What to do: the short version
When to call a technician and what they will do
An occasional top-up at the start of the season is routine. But if the system has to be topped up every few days or weeks, that is no longer maintenance but a sign of a fault. The Immergas manual says so clearly: frequent pressure drops point to a possible leak in the system. When a system is topped up with fresh mains water over a long period, new minerals and oxygen keep entering it, which speeds up the build-up of deposits and corrosion in the heat exchanger.
On arrival the technician first checks the pre-charge pressure of the expansion vessel and restores it if necessary, then inspects the safety valve, the filling tap and the connections inside the boiler. If everything in the boiler is tight, the leak is sought in the system itself. When it cannot be seen, leak detection helps. Our technicians carry many of the parts needed for this, such as expansion vessels and valves, in their vans, so the fault can usually be fixed in a single visit.
Frequently asked questions
What should the pressure be in a gas boiler?
For most domestic boilers the cold-system pressure should be 1–2 bar. For example, Vaillant ecoTEC plus specifies 1,0–2,0 bar, Immergas Victrix Tera 1,0–1,2 bar, Baxi Luna Duo-tec E 1,0–1,5 bar. The exact limit is given in your boiler's manual.
Is it normal for the pressure to rise during heating?
Yes. Water expands as it heats up, so the pressure in a warm system is slightly higher than in a cold one. It is only worth worrying when the pressure approaches 3 bar or the safety valve drips.
How often is it normal to top up the system?
In a leak-tight system the pressure holds for months. You may need to top up after bleeding the radiators, at the start of the season or in the first weeks after installation. If you have to top up every few days or weeks, it is a sign of a fault.
I have overfilled the system. What should I do?
With the system cold, let a little water out through a radiator bleed valve into a container until the pressure returns to normal. If you are not sure, call a technician.
Can I top up while the boiler is hot?
Better not. A hot system shows a higher pressure, so it is easy to add too little or too much. Manufacturers tell you to check and top up the pressure with the system cold.
What does pressure in megapascals mean?
1 bar is 0,1 MPa. If the display shows 0,12 MPa, that is 1,2 bar.
Need a technician?
We have worked across Lithuania since 2016 and arrive with spare parts. Describe the situation or give us a call.
Sources
- Vaillant ecoTEC plus VU/VUW, installation and maintenance manual, doc. 0020308118_05 (2023-05-31), section 9.7 "Ensuring the system pressure"
- Immergas Victrix Tera V2 24-35 Plus EU, user and installation manual, doc. 1.047821ENG
- Baxi Luna Duo-tec E, operating and installation instructions, doc. 7720148 (01-10/18)
- Viessmann Vitodens 100 WB1A, installation and maintenance manual, doc. 5862 981 GB (2006-06)
- Viessmann Vitodens 100-W B1HF, B1KF, installation and maintenance instructions, doc. 6135835 FR (2021-10), fault messages
- Bosch Condens 2300i W, installation and maintenance manual, doc. 6720878837 (2025/12), table of messages
This article is general information. Always follow the manual of your own boiler, and leave work on gas and combustion components to a certified specialist.