Heating system flushing: when it is essential and how it is done
You never see the water in your heating system, yet over a year it travels round the loop thousands of times: through the boiler, the pipes and the radiators. If that water is clean, the system runs quietly and evenly. If rust particles, limescale and sludge build up in it, the radiators heat unevenly, the pump works harder and the boiler's heat exchanger gradually clogs. In this article we explain where the dirt comes from, how to tell that it is time to flush the system, and what to do so that the water stays clean after flushing.
In brief
- Dirt in the system comes from rust, limescale and installation residues, especially when oxygen gets into the system.
- The most common signs: the bottom of the radiators is cool, the boiler is noisy, the pump fails often or the filter clogs.
- Manufacturers themselves specify that the system should be flushed before a new boiler is installed.
- After flushing it is worth fitting a magnetic filter and using only additives approved by the manufacturer.
- Frequent topping up harms the system: fresh water brings in oxygen and limescale.
What builds up in a heating system
A heating system is a closed loop, so it would seem that the water in it should always stay clean. In practice dirt comes from several sources:
- Rust and magnetite. Steel radiators and pipes slowly corrode from the inside, especially when oxygen gets into the water. This produces fine black particles of iron oxide known as magnetite. They are heavy, so they settle in the lower parts of the radiators, while others collect in the pump and the boiler's heat exchanger.
- Limescale. When hard water is heated, the dissolved minerals settle on the hottest surfaces, first of all on the boiler's heat exchanger.
- Installation residues. After repairs or new pipework, soldering flux, oil or fine metal swarf remain in the system.
- Unsuitable additives. Not all antifreezes, sealants or other fluids are compatible with the boiler. Manufacturers warn that unsuitable additives can change the properties of components and cause noise and damage.
How to tell that it is time to flush the system
None of these signs on its own means that the system is contaminated, but several together are a good reason to call a technician:
- The bottom of the radiator is cool and the top is warm. This is the opposite of what air does, when the top stays cold. A cool bottom often means that deposits have collected there.
- Individual radiators heat poorly, even though the air has been bled and the thermostatic valves are open.
- The boiler is noisy, with a gurgling or "kettling" sound. This can be a sign of deposits in the heat exchanger.
- The pump fails often, or the technician finds black deposits in it when replacing it.
- The filter clogs again soon after cleaning, and the drained water is dark or black.
During a service the technician can also check the water itself. Manufacturers' manuals describe how this is done: a little system water is drawn off and inspected for deposits, a magnetic rod is used to check for magnetite, and the pH is measured. For example, Vaillant specifies that the pH of water at 25 °C must be between 8,2 and 10. If the water is contaminated or the pH is outside this range, the system has to be cleaned and the water treated.
When flushing is essential
- Before a new boiler is installed. Manufacturers include this step in their installation manuals. A new condensing boiler has narrow passages, and the old sludge would be enough to foul it within the first season. We describe the whole replacement in more detail in the article "Boiler replacement from A to Z".
- When magnetite or deposits are found in the water, the pump or the filter.
- After major work on the system: when radiators or pipework have been replaced or a new part of the system has been connected.
- When pump or heat exchanger faults keep recurring and the cause is the water rather than the parts themselves.
How flushing is done
Depending on how contaminated the system is, flushing can be simple or done with cleaning agents. Manufacturers' manuals describe this basic principle: the system is flushed at least twice, once with cold water and once with hot.
- Preparation. All thermostatic radiator valves and the boiler isolation valves are opened, and a hose is connected to the drain valve at the lowest point of the system.
- "Cold" flush. The water is drained from the system quickly, with the radiator air vents opened as well, so that all the contaminated water runs out. The system is then refilled.
- Cleaning with agents, if needed. If there is a lot of dirt, a cleaning agent that loosens the deposits is added to the system. Manufacturers specify that only agents compatible with their boilers may be used and that the system must be flushed again afterwards. For heavily contaminated systems a special flushing pump is used, which drives water at high speed through each radiator separately.
- "Hot" flush. The boiler is run until the system warms up, the system is checked for leaks, and then the water is drained quickly again.
- Filling. The system is filled with treated water, the air is bled and the required pressure is set.
Chemical descaling of the boiler's or water heater's heat exchanger is a separate job. It is needed when limescale settles in the hot water heat exchanger and the boiler no longer produces enough hot water. We carry out this work as chemical flushing of a gas boiler.
How to protect the system after flushing
Magnetic filter
A magnetic filter fitted on the return pipe before the boiler catches rust particles before they reach the pump and the heat exchanger. The technician cleans it during the annual service. Manufacturers list such a filter as one of the corrosion protection measures.
Suitable water
Not all mains water is suitable for a heating system. Manufacturers specify when the filling water has to be treated, i.e. softened or otherwise conditioned. For example, Vaillant requires this if more than three system volumes of water are added over the whole life of the system, if the water hardness exceeds the stated limits or if the pH is outside the 8,2–10 range. The hardness limits depend on the boiler output and the system volume: the more water in the system per kilowatt, the softer the water needs to be.
Top up as rarely as possible
Every time the system is topped up, oxygen and limescale come in with the fresh water. So if you often have to raise the pressure, look for the cause: a leak, a faulty safety valve or expansion vessel. We explained how to do this in the article "Boiler pressure".
Approved additives only
Antifreezes, corrosion inhibitors and sealants must be compatible with your boiler. Manufacturers' manuals usually list which additives have been tested. An unsuitable sealant or other fluid added without the technician knowing can damage boiler components, and flushing it out later is difficult.
Tip: ask the technician to write down after flushing when it was done, what the water pH was and which additives were used. This information will be useful at the next service.
Frequently asked questions
How often does a heating system need flushing?
There is no set interval. It is worth flushing the system when deposits or magnetite are found in the water, the filter or the pump, before a new boiler is installed and after major work on the system.
Can I flush the heating system myself?
Draining the water from the system is not difficult, but flushing it properly, choosing the cleaning agents and preparing the new water is best left to a technician. Unsuitable agents or leftover cleaner can damage the boiler.
Why is the bottom of the radiator cold and the top hot?
Usually because deposits have collected at the bottom and are obstructing the water flow. If it is the top that stays cold, the cause is usually air in the radiator.
Is a magnetic filter really necessary?
It catches rust particles before they reach the pump and the heat exchanger. Manufacturers list it as one of the corrosion protection measures, especially in old systems with steel radiators.
Need a technician?
We have worked across Lithuania since 2016 and arrive with spare parts. Describe the situation or give us a call.
In the online shop
Sources
This article is general information. Always follow the manual of your own boiler, and leave work on gas and combustion components to a certified specialist.