Boiler won't switch on or heat: what to check before calling a technician

Updated 10 November 2026 · 6 min read · Prepared by the technicians of Visų katilų remontas

A cold evening, and the radiators are cool. Or the other way round: the house is warm, but only cold water comes out of the tap. The first thought is of an expensive fault, but the cause is often simpler: flat thermostat batteries, low pressure or a closed valve. In this article we have listed the checks from the simplest to the more involved. Each of them is safe and permitted by manufacturers' instructions. If they do not help, it is time to call a technician.

In brief

  • First, see whether the boiler display is lit and whether it shows an error code.
  • Check the pressure, the gas isolation valve before the boiler and the room thermostat.
  • If only some radiators are cold, the usual cause is air in the system or closed valves.
  • If there is heating but no hot water (or vice versa), the fault is usually inside the boiler.
  • Do not check the gas, combustion or electrical components yourself. If you smell gas, go outside and call 112.

First: what the boiler shows

Before doing anything, go to the boiler and look at it carefully. The boiler tells you a lot by itself; you just need to know how to read the signs.

F.28 21° 12345 displaypressuregasthermostatradiators
Order of checks: display, pressure, gas, thermostat and radiators. You can check most of these in a few minutes.
  • The display is dark. The boiler has no power. Check that the plug is in the socket, that the switch next to the boiler has not been turned off and that the circuit breaker in the consumer unit has not tripped. If it trips again, do not keep resetting it: that is already a sign of a fault.
  • There is an error code on the display. Write it down. We have explained what the most common codes mean in the article "Boiler error codes".
  • The display is lit, there is no code, but the boiler is silent. Most likely the boiler is simply not being told to heat. More on that below.

Check the pressure

Low pressure is one of the most common reasons a boiler stops. Most boilers then switch off the burner and show a code, for example Vaillant F.022 or Immergas 10. Look at the pressure gauge: with the system cold, the pressure in most boilers should be between 1 and 2 bar. If it is lower, top up the system as described in the article "Boiler pressure".

Is there gas

When the flame does not light, the boiler tries again several times and then locks out. Check that the gas isolation valve before the boiler is open: its handle should be in line with the pipe. See whether other appliances, such as the hob, have gas. If there is no gas anywhere in the house, contact your gas supplier. If there is gas and the valve is open, reset the boiler once. If the code comes back, call a technician.

If you heat with LPG from a cylinder or a tank, check whether there is any left. In cold weather the cylinder pressure drops, so the boiler may fail to light even when the cylinder is not completely empty.

If you smell gas, do not check anything. Do not switch any switches on or off, do not light a flame, open the windows, close the gas isolation valve if possible, go outside and call 112 from there.

Is the boiler being told to heat

A boiler heats only when it is "told" to by the room thermostat, the timer or the boiler's own settings. If the display is lit, there is no error and the burner does not light, check:

  • The heating mode. Many boilers have a summer mode in which only hot water is produced. Once it is switched on in spring, it is easy to forget about it in autumn.
  • The room thermostat. Is the set temperature higher than the current one? Are the batteries flat? Wireless thermostats sometimes lose the connection with the receiver at the boiler.
  • The timer and programme. Is a night or "away" mode set?
  • The heating temperature on the boiler. On cold days a temperature set too low looks like "no heating".

If the burner lights after you change the settings, there was no fault. If the boiler still does not switch on although all the conditions are met, the fault is in the boiler or its controls.

The boiler runs but the radiators are cold

It also happens that the boiler hums and the flame burns, yet the rooms are cold. Then the problem is usually not in the boiler but in the heating system.

  • A radiator is cold at the top and warm at the bottom. Air has collected in it. Once the radiator has cooled down, bleed the air through the valve in the top corner and then check the pressure. How to do this is described in the guide to bleeding radiators.
  • Only one or a few radiators are cold. Check that their valves and thermostatic heads are open. After the summer the pin of a thermostatic valve sometimes sticks and no longer opens.
  • Only the radiators closest to the boiler are warm. The water is circulating too weakly. Possible causes are an unbalanced system, a clogged filter or a pump fault. This is a job for a technician.
  • Underfloor heating warms up slowly. This is normal: a thick floor layer takes several hours to warm up, so it should not be judged in the same way as radiators.

There is heating but no hot water (or vice versa)

A combi boiler provides both heating and hot water, and a three-way valve switches it between the two. If only one function works, the cause is usually inside the boiler and you will need a technician. Manufacturers' servicing tables mention these components:

  • The three-way valve sticks in one position. Then the boiler, for example, heats the radiators when you open a hot tap.
  • The flow sensor no longer detects that you have opened a tap, so the boiler does not even try to heat water.
  • The cold water inlet strainer becomes clogged, and the hot water flow turns weak.
  • The secondary (hot water) heat exchanger becomes scaled, so the water no longer reaches the required temperature.

If hot water is produced in a separate water heater, check its set temperature and whether hot water production has been switched off in the boiler settings.

In winter: a frozen condensate pipe

A condensing boiler produces condensate, which is led to the drain through a small pipe. If this pipe runs outdoors or through an unheated room, it can freeze in cold weather. The condensate then has nowhere to go and the boiler stops, often with a flame or condensate error code. That is why manufacturers require the annual service to include a check that condensate pipes running outdoors are of sufficient diameter and insulated.

If you suspect the pipe has frozen, you can thaw it carefully with warm (not boiling) water or a warm towel and then reset the boiler. Do not heat the pipe with a flame or a hot air gun. If the pipe freezes every year, it needs to be rerouted or insulated.

When you need a technician

If you have done all the checks described above and the boiler still does not work, it is time to call. Also call a technician straight away if:

  • the same error code comes back after a reset;
  • the circuit breaker in the consumer unit trips;
  • there is water under the boiler or the safety valve is dripping;
  • the boiler makes unusual noises: loud humming, knocking, whistling;
  • the flame is yellow, or soot has appeared on the boiler or the wall;
  • you smell flue gases or burning.

When you call, tell us the boiler model, the error code and what you have already checked. This saves time, and our technicians carry the most commonly replaced parts with them, so a large share of faults can be fixed in a single visit. If the boiler has stopped during a cold spell, see the terms of an emergency call-out.

Frequently asked questions

The boiler won't switch on and the display is dark. What should I do?

Check that the plug is in the socket, that the switch next to the boiler is on and that the circuit breaker in the consumer unit has not tripped. If the breaker trips repeatedly, do not try to switch it on again; call a technician.

Why does the boiler produce hot water but not heat the radiators?

Usually summer mode is on, the room thermostat is not calling for heat or the heating temperature is set too low. If the settings are correct, the three-way valve may be stuck, and a technician is needed.

Why does the heating work but there is no hot water?

In a combi boiler the most common causes are the three-way valve, the flow sensor, a clogged cold water strainer or a scaled hot water heat exchanger. This is a job for a technician.

A radiator is cold at the top. Is that a fault?

Usually not: air has collected in it. Bleed the air through the radiator's bleed valve and check the boiler pressure, because it may drop.

Can I thaw a frozen condensate pipe myself?

You can thaw it carefully with warm water or a warm towel and then reset the boiler. Do not use a flame or a hot air gun. If the pipe freezes often, it needs to be insulated or rerouted.

Need a technician?

We have worked across Lithuania since 2016 and arrive with spare parts. Describe the situation or give us a call.

Tips: Boiler not heating

Write the boiler manufacturer and model or attach a photo of the rating plate – we will call you and help.

+370 630 13331Request a service

Sources

  1. Vaillant ecoTEC plus VU/VUW, installation and maintenance instructions, doc. 0020308118_05 (2023-05-31): safety section 1.3, maintenance table (Appendix B), fault codes (Appendix F)
  2. Viessmann Vitodens 100-W B1HF, B1KF, installation and maintenance instructions, doc. 6135835 FR (2021-10), fault messages
  3. Immergas Victrix Tera V2 24-35 Plus EU, user and installation manual, doc. 1.047821ENG
  4. Bosch Condens 2300i W, installation and maintenance instructions, doc. 6720878837 (2025/12)

This article is general information. Always follow the manual of your own boiler, and leave work on gas and combustion components to a certified specialist.