Skip to content

Mon–Fri 8–18

We work across Lithuania
Advice

When and why gas boilers break down: statistics from our jobs

Updated 26 November 2026 · 5 min read · Prepared by the technicians of Visų katilų remontas

In this article we share our own job statistics: when customers most often call a technician about a fault, when they book a service, which makes of boiler we service and which fault topics our technicians record most often. The data comes from our job register and contains no customer details, only totals.

In brief

  • Repair call-outs peak in October–December, when the heating season starts. The fewest are in June.
  • Services peak in September and October, when technicians are also busy with repairs.
  • We recommend planning the service for April–July, especially June: it is easier to get a time that suits you.
  • The boilers we service most often are Junkers / Bosch, Viessmann and Immergas. This shows which boilers our customers have, not which are more reliable.
  • The most common fault topics in technicians’ notes: pressure and the expansion vessel, ignition and flame, the control board.

Source: Ronali job register, closed jobs, 01/2023 – 11/2026. Figures are rounded; we explain how they were calculated at the end of the article.

When boilers break down most often

In 2023–2025, repair call-outs peaked in October, November and December. In October we had on average 191 repair call-outs, and in June, the quietest month of the year, 59. Faults that went unnoticed in summer probably show up once the heating season starts, because the boiler was idle or only heating hot water.

In some years the high number of call-outs continues through the winter: in January 2026 we registered 330 repair call-outs, the most in the whole period.

Services peak earlier: September and October. Many customers book a boiler check just before the heating season, so in autumn technicians are busy with both services and repairs. In October 2026 we carried out 645 services, the most in a single month.

Average jobs per month, 2023–2025 repair call-outs services 0200400600 JanFebMarAprMayJunJulAugSepOctNovDec 19159559245 Source: Ronali job register, closed jobs
Average number of repair call-outs and services per month, 2023–2025. 2026 is not included in the average because the year is not over yet.
MonthRepair call-outs (average)Services (average)
January65367
February98307
March97285
April83284
May91329
June59245
July85362
August97395
September102478
October191595
November154424
December146323

What this means for you: don’t plan the service for autumn

We recommend booking the service for April–July, and if you can choose, June. That is when technicians are least busy: in June we did on average 59 repairs and 245 services, and in October 191 repairs and 595 services. In a quieter period it is easier to agree on a day and time that suit you.

There is also a practical benefit: if the service shows that a part needs replacing, there is time to order and fit it before the heating season. We describe what the technician does during a service in “Annual boiler maintenance”, and how to get ready for autumn in “Getting ready for the heating season”.

Which boilers we service most often

The table shows how many boilers of each make are in our job register. It shows which boilers our customers have, not which boilers are more reliable or break down more often. We do not rate makes by reliability: this data is not suitable for that.

ManufacturerBoilers in the register (approx.)
Junkers / Bosch1 830
Viessmann1 820
Immergas1 370
Protherm560
Baxi550
Vaillant470
Buderus350
Radiant170
Wolf160
Sime110
Ariston100

We show Junkers and Bosch together because newer Junkers boilers are sold under the Bosch name and the two names are mixed in the register. Separately, about 1,170 boilers are marked as Junkers and about 650 as Bosch.

Most common fault topics

After a repair the technician briefly records in the register what they found. We grouped these notes into topics by keywords. The topic was clear in 1,326 records, so the percentages are calculated from those only. Records without a note and notes that could not be assigned to any topic are not included in the table.

TopicRecordsShare
Pressure, expansion vessel38929 %
Ignition, flame25719 %
Control board17513 %
Pump1149 %
Thermostat816 %
Flue615 %
Sensors594 %
Condensate574 %
Fan524 %
Heat exchanger, limescale494 %
Three-way valve252 %
Gas valve7less than 1 %

What each topic means:

  • Pressure, expansion vessel. The system pressure drops or rises, often because of the expansion vessel or a leak, and the boiler switches off. More: “Boiler pressure”.
  • Ignition, flame. The boiler does not light or the flame goes out, and the boiler locks out with an error code. More: “Error codes”.
  • Control board. The electronic board controls everything the boiler does, and its failure often shows up as error codes or a frozen display. More: “Error codes”.
  • Pump. The circulation pump pushes water through the radiators, and when it fails the boiler runs but the radiators stay cold. More: “Boiler not heating”.
  • Thermostat. The room thermostat or its connection to the boiler does not pass on the call for heat, or switches the boiler on too often. More: “Boiler switches on often”.
  • Flue. The flue carries away the combustion products, so a leak or blockage in it is also a safety issue. More: “Carbon monoxide and gas safety”.
  • Sensors. A temperature or pressure sensor gives inaccurate readings and the boiler stops with an error code. More: “Error codes”.
  • Condensate. A blocked condensate pipe, or one frozen in winter, stops a condensing boiler or starts to drip. More: “Boiler leaking”.
  • Fan. The fan supplies air for combustion, and when worn it hums, squeals or stops the boiler from lighting. More: “Noisy boiler”.
  • Heat exchanger, limescale. Sludge and limescale in the heat exchanger reduce heat transfer and can cause a “kettling” noise. More: “Heating system flushing”.
  • Three-way valve. The valve switches the boiler between heating and hot water, and when it sticks one of them is left without heat. More: “Boiler not heating”.
  • Gas valve. The gas valve regulates the gas supply to the burner, and only a certified technician may check, adjust or replace it.

If you smell gas, do not switch any electrical switches on or off and do not light a flame. Open the windows, close the gas valve if you can, go outside and from there call the gas emergency service on 1804 or 112. Do not open the boiler casing or touch gas parts yourself.

How we counted and what this data does not show

  • Source. Ronali job register, closed jobs, 01/2023 – 11/2026. We used totals only, without customer names or addresses.
  • Repair call-outs and services. Jobs are grouped by how they are marked in the register: fault call-out or preventive service. Other jobs, such as installation or commissioning, are not included in the chart.
  • Monthly averages. We calculated them from the full years 2023, 2024 and 2025 only. We did not include the months of 2026 in the average, and November 2026 is not over yet. The number of jobs grew every year, so the average shows the shape of the season, not the exact number in a given year.
  • Makes. We merged spelling variants of the same make (for example, “Viessman” and “Viessmann”). Records without a make or with an unclear name were not counted. Figures are rounded to the nearest ten.
  • Fault topics. Each repair record was assigned to one topic based on keywords in the technician’s note. The topic was clear in only about a quarter of repair records, so the table shows the most common topics, not an exact breakdown of all faults. A keyword shows what the technician mentioned, but not always the exact cause of the fault.
  • What it does not show. The data reflects our customers and their boilers, not the whole Lithuanian market. We draw no conclusions from it about the reliability of makes or the age of boilers: the register lacks the data for that.

Frequently asked questions

In which months do gas boilers break down most often?

According to our 2023–2025 data, repair call-outs peak in October, November and December, when the heating season starts. The fewest are in June.

When is the best time to book a boiler service?

We recommend April–July, and if you can choose, June. That is when technicians are least busy, while September–December is the busiest period.

Do these statistics show which make of boiler is the most reliable?

No. The makes table shows which boilers our customers have. We do not assess reliability from this data, because the number of repairs depends more on how many customers, and which ones, we serve.