Refrigerant replacement

Refrigerant is the substance that makes heat exchange possible in heat pumps and air conditioners. Over time the amount of refrigerant in the system can drop because of a leak, which directly affects the efficiency of the unit and its heating or cooling output. Refrigerant replacement and top-up is done only by certified specialists with special equipment – anywhere in Lithuania.

What is refrigerant and why does it RUN OUT?

Refrigerant is a special fluid that circulates in the system of a heat pump or air conditioner and transfers heat between the indoor and outdoor units. In a closed system the amount of refrigerant should not decrease – if it is low, there is a leak in the system.


The most common causes of low refrigerant:

A leak in the pipes or connections

Caused by mechanical damage, corrosion or incorrect installation.

Heat exchanger damage

A cracked or damaged heat exchanger can cause a refrigerant leak.

Incorrect installation

Poorly tightened connections or poor-quality installation work.

Important: Before topping up the refrigerant, the leak must be found and fixed – otherwise the top-up will be only a temporary solution.

Signs that the refrigerant needs replacing

Contact a specialist if you notice at least one of these signs:

The unit heats or cools worse than usual. Rooms do not reach the set temperature even though the system is running at full capacity.

Higher electricity consumption. When refrigerant is low, the unit works harder and uses more electricity.

The heat exchanger ices up heavily. Constant or heavy icing usually points to low refrigerant.

Frequent shutdowns or error codes. The system shuts down by itself or shows error codes on the control panel.

A chemical smell. A distinctive smell near the unit may mean a refrigerant leak.

How is refrigerant replacement done?

01
Diagnostics and leak detection The specialist checks the refrigerant pressure in the system and determines whether there is a leak. The leak is located with a special detector or a tracer dye.
02
Fixing the leak Before the refrigerant is topped up, the leak must be fixed – the connection is repaired, or the damaged pipe or heat exchanger is replaced. Without this step the top-up would be only a temporary solution.
03
Removing the old refrigerant If the refrigerant is contaminated or of the wrong type, what is left of it is recovered with special equipment before the new refrigerant is added.
04
Topping up the refrigerant The system is topped up with the required amount of refrigerant according to the manufacturer's specifications. Only the correct type of refrigerant, as stated in the unit's technical documentation, is used.
05
Pressure check and testing After the top-up the system pressure and temperature are checked. The system is started and tested in heating and cooling modes to make sure the unit works efficiently.
06
Report The customer is told what work has been done and how much refrigerant was used, and receives recommendations for further maintenance.

Which units do we service?

We replace and top up refrigerant in all types of units:

Air-to-air heat pumps

Split and multi-split systems.

Air-to-water heat pumps

Connected to an underfloor heating or radiator system.

Air conditioners

Air conditioners for homes, offices and commercial premises.

Cassette and ducted units

Units for commercial and larger premises.

We work with equipment from all the main manufacturers: Daikin, Mitsubishi, Panasonic, Bosch, Vaillant, Viessmann and others.

FREQUENTLY ASKED QUESTIONS

Here you will find answers to some of the most frequently asked questions about refrigerant replacement.

Can I top up the refrigerant myself?

No. Refrigerant replacement requires certified specialists and special equipment. Handling refrigerant yourself is dangerous and prohibited under EU regulations. Besides, unless the leak is fixed, a top-up will be only a temporary solution.

How often does refrigerant need replacing?

In a closed system the amount of refrigerant should not decrease. If it needs topping up often, there is a leak in the system that must be fixed. A properly installed and maintained system should not need a refrigerant top-up for many years.

How long does refrigerant replacement take?

A simple refrigerant top-up takes 1–2 hours. If a leak has to be found and fixed, the work may take longer, depending on where the leak is and how complex it is.

Is the refrigerant the same in all units?

No. Different units use different types of refrigerant (R32, R410A, R290 and others). Using the wrong refrigerant is prohibited; it can damage the unit and void the warranty. Our specialists always use the type of refrigerant specified by the manufacturer.

Is your unit heating or cooling worse than usual? Get in touch – we will find the cause, fix the leak and top up the refrigerant anywhere in Lithuania.

REGISTER
+370 630 13331

OUR PARTNERS

We are official representatives of these companies:

Viessmann, Immergas, Vaillant, Sime, Baxi, Wolf, Protherm, Rotenso, Ravenheat, Bosch, Junkers, Buderus.

visukatiluremontas.lt – refrigerant replacement across Lithuania

visu katilu remontas wolf visu katilu remontas viessman visu katilu remontas immergas visu katilu remontas bosch visu katilu remontas baxi visu katilu remontas acv visu katilu remontas buderus visu katilu remontas die dietrich visu katilu remontas junkers visu katilu remontas baretta visu katilu remontas protherm visu katilu remontas ravenheat visu katilu remontas vailant
visu katilu remontas wolf visu katilu remontas viessman visu katilu remontas immergas visu katilu remontas bosch visu katilu remontas baxi visu katilu remontas acv visu katilu remontas buderus visu katilu remontas die dietrich visu katilu remontas junkers visu katilu remontas baretta visu katilu remontas protherm visu katilu remontas ravenheat visu katilu remontas vailant
CallRegister